CONTEC R100 Positive Airway Pressure Devices CPAP Machine with Humidity Regulation

$762.12
In Stock
  • Fast shipping and delivery.
  • Easy return and refund.
  • Online customer support 24/7
SKU: 1005005495253357
Category:

Description

  • Origin: CHINA
  • Model Number: R100
  • Brand Name: Contec
  • Mode: Auto CPAP Mode
  • Scope of use: Home, Clinic and Hospital Use
CONTEC R100 Positive Airway Pressure Devices CPAP Machine with
                Humidity Regulation
 
 
 
 

 
 

Introduction

Positive airway pressure device is a portable respiratory therapy device, treating obstructive sleep
apnea (OSA). It can be applied on patients weighing above 30 kg. It is suitable for family use, clinic
use and hospital use.

Product Functions 
1)CPAP/Auto CPAP treatment mode can adjust operating pressure;
2)Provide mask leakage detection,leakage prompt and error status prompt;
3)Automatically compensate air leakage within a certain range;
4)Saving and checking patients information;
5)Capable of recognizing whether the mask is on or off and starting and stopping treatment intelligently;
6)Setting Ramp time, Humidity level between 1 and 6;
7)Auto pressure release;
8)Multiple remind functions.

Performance
Operating Pressure:
1)Operating pressure range:4 cmH2O~20 cmH2O(4~ 20 hPa)
2)Resolution ratio :0.1cmH2O(0.1 hPa)
3)Dynamic variation range:0.2 cmH2O(0.2 hPa)
Ramp Time:
1)Operating range:0~45 min
2)Resolution ratio :1min
3)Dynamic variation range:5 min
Power:
1)Input:100-240 V~,50-60 Hz;1.5 A MAX
2)Output:DC 24 V 3.75 A
Humidifier:
1)Volume:200ml~360ml
2)Consumption:≤48W
3)Materials: PC, Stainless steel chassis
4) Maximum temperature of hating plate:63℃ (±3℃)
5)The air outlet temperature of Breathing tube:≤41℃
6)Thermal circuit breaker: disconnection>85±5℃, recovery<55±15℃, delay< 10s, DC24V-3A,
7)Protective disconnection temperature: 76℃
Safety Classification :
1)(Anti-electric shock level ) : Class II and Type BF applied part
2)SpO2 Device:Class I laser product   
3)Ingress protection:IP22
SpO2 Measurement:
1)Measurement range:0%~100%
2)Resolution ratio:1%
3)Accuracy:±2%
PR Measurement:
1)Measurement range:30 bpm~250 bpm
2)Resolution ratio:1bpm
3)Accuracy:±2 bpm or ±2% of the maximum  
Noise :
1)Pressure is 10 cmH2O, distance is 1m, normal operation (including humidifier) noise ≤35dB 
Operating Measurement:
1)Flow Sensor ±500Pa
2)Pressure Sensor 0~45 cmH2O(0~45 hPa)
Accessories
Breathing tube (Breathing circuit)
Breathing tube (Breathing circuit) Specification
Micro SD Card
SpO2 Device (Optional)
Mask
Mask Specification
Power Supply Unit
Power adapter cord 
Air Inlet Filter Cotton
Portable bag 
The User Manual
Reminder: Breathing tube (Breathing circuit) refer to the physical products.

Physical Specification
Dimensions: 275*170*145 mm
Breathing tube:Soft plastic, length is 1.8m, outlet complies with ISO5356.1 22mm conical joint
Weight(device and cleanable humidifier):1600g
Work Environment:
a)Operating Temperature:+5 ℃~+40 ℃
b)Relative Humidity:10%~95%, non-condensing
c)Atmospheric Range (non-condensing):700 hPa~1060 hPa

Additional information

Color

R100

Origin

CHINA

Model Number

R100

Brand Name

Contec

Mode

Auto CPAP Mode

Scope of use

Home, Clinic and Hospital Use

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.